Free and Forced Convection Unit - LTek Online
Free and Forced Convection Unit manufacturers & OEM manufacturers India. Free and Forced Convection Unit Suppliers, Free and Forced Convection Unit Exporters
Free and Forced Convection Unit
Free and Forced Convection Unit
Product Code: LTEKCTLB-TTE60-0059

Tenders Description & Specification for Free and Forced Convection Unit

Free and Forced Convection Unit

The heat transport is substance-bound. The heat transport is substance-bound. In the convection process, the whole fluid is moving. So-called bulks of fluid move (and thus transfer heat) from warm zones into cold zones The different temperatures lead to density differences in the fluid so that a flow develops. In the case of forced convection, The flow is generated by a fan or pump. In this case, the heat transfer to fluid particles is lower, but more heat is transported than with free convection due to the much larger mass flow. In the case of free convection, the density differences result in a rather slow flow of the fluid with a more intensive heat transfer. 
The core element of the experimental unit is a vertical duct into which a heating element is inserted. Sensors record the flow velocity of the air, the heating power and the temperatures at all relevant points. The well-structured instructional material sets out the fundamentals and provides a step-by-step guide through the experiments. Three flows elements with different surfaces are available: a flat plate, a tube bundle Or fins. For experiments on forced convection, an additional fan has to be activated. 

Learning Objectives / Experiments
Flat plate
Pipe bundle
Fins
Temperature distribution in the heat exchanger
Determination of the Reynolds and Nusselt numbers
Free and forced convection
Heat transfer at different surfaces:
Calculation of heat transfer coefficient for free and
Forced convection

Specification:
Air duct with axial fan
3 heating elements with different surfaces: flat plate, tube bundle or fins
Heat transfer in the air duct by free and forced convection
Sensors measure temperatures (upstream and downstream of the heating element and inside the heating element), flow velocity of the air and heating power

Technical Data
Axial fan
Max. volumetric flow rate: 170m3/h
Max. pressure difference: 54Pa
Power consumption: 6,5W
Nominal speed: 2900min-1
Air duct
Flow cross-section: 120x120mm
Height: 1m
Heating elements
Temperature limitation: max. 150°C
Max. heating power: 200W
Surface of flat plate: 140cm2
Surface of tube bundle: 980cm2
Surface of fins: 1400cm2
Measuring ranges
Flow velocity: 0…10m/s
Temperature: 2x 0…100°C, 1x 0…200°C
Heating power: 0…375W.

Ltekonline are the manufacturers of Free and Forced Convection Unit used to demonstrate engineering principles in Engineering Colleges, Engineering Schools and Thermal Training Equipment for Engineering Teaching Lab in Universities

Categories: Thermal Training Equipment

Tags: Free and Forced Convection Unit

Free and Forced Convection Unit Related Products

Other Highly Specialized Products for Engineering Lab, Technical Educational Lab and Scientific Lab Equipments such as Free and Forced Convection Unit