Tenders Description & Specification for Installation Technology: Losses In A Pipe System
Installation Technology: Losses In A Pipe System
Learning Objectives / Experiments
Influence of pipe diameter, flow velocity, change in cross-section and pipe fittings on the pressure losses
Determination of pump characteristics, system characteristics and the operating point
Pressure curve in a closed pipe system with circulation pump.
Specification:
Pipe elements are commercially standard components in heating and sanitary engineering
Clear panel mounted on a sturdy, movable frame
Closed water circuit with pump and tank
Investigation of the pressure losses at contractions, pipe angles, pipe bends, valves and fittings and pipe elements of different diameter
Measurement of the pressure distribution at
13 pressure measuring points, display with 13 tube manometers
Integrated bleed valve on manometer and in the pipe section
Flow measurement using rotameter.
Technical Data:
Pump – 3 stages – max. flow rate: 4,5m³/h – max. head: 6m
Tank: approx. 5L
Required for Operation
230V, 50Hz, 1 phase
Measuring range – flow rate: 100…1000L/h – pressure: 1600mmWC
Dimensions and Weight LxWxH: 1900x700x2020mm
Weight: approx. 140kg.
Ltekonline are the manufacturers of Installation Technology: Losses In A Pipe System used to demonstrate engineering principles in Engineering Colleges, Engineering Schools and Thermal Training Equipment for Engineering Teaching Lab in Universities