Tenders Description & Specification for Low-Voltage Power Supply & Distribution Assessment Training System
Electrical Skills Training Low-Voltage Power Supply & Distribution Assessment Training System
A. Technical Parameters:
Working environment
Air clean, non-corrosive and explosive gases, non-conductive and no dust damaged the insulation.
No significant vibration and shock vibration. Vertical installation, the tilt ≤5°
Ambient temperature ≤+40℃,≥ -5℃ the average temperature ≤ +35℃ within 24 hours
The relative humidity ≤50% at the maximum temperature +40℃, allowing a higher relative humidity at lower temperatures, such as +20℃when 90%;
Altitude ≤2000 meters
Transport and storage within temperature;-25℃to +55℃.In a short time ≤+70℃(≤24 hours).
B. Technical Parameters
Rated insulation voltage: DC 660V
Rated working voltage: AC 380V
Branch bus rated current: 10-16A;
Bus rated current: 100A
Auxiliary circuit Rated working voltage: AC 380V, 220V
Product composition:
High and voltage switchgear analog indicate wall 1 set
Analog transformer 1 set
High voltage cabinet 1 set
Low voltage cabinet 1 set
Basic Experiment and Operation:
High voltage cabinet mechanical locking operation instruction.
High voltage cabinet closing and energy storage operation instruction.
High voltage analog wall wiring operation instruction.
Power compensation operating instruction.
Low voltage distribution output operation instruction.
Low voltage cabinet reactive power automatic compensation controller operation instruction.
Ltekonline are the manufacturers of Low-Voltage Power Supply & Distribution Assessment Training System used to demonstrate engineering principles in Engineering Colleges, Engineering Schools and Electrical Trainer Kit for Engineering Teaching Lab in Universities